<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
	<Article>
		<Journal>
			<PublisherName>Colegio Argentino de Cardioangiólogos Intervencionistas</PublisherName>
			<JournalTitle>Revista Argentina de Cardioangiología intervencionista</JournalTitle>
			<PISSN>2250-7531</PISSN>
			<EISSN>2313-9307</EISSN>
			<Volume>4</Volume>
			<Issue>01</Issue>
			<PubDate PubStatus="epublish">
				<Year>2013</Year>
				<Month>3-</Month>
				<Day>20</Day>
			</PubDate>
		</Journal>

<ArticleTitle>Trans-catheter aortic valve implantation (TAVI)  in the catheterization laboratory: challenges  and problem solving</ArticleTitle>
<FirstPage>0018</FirstPage>
<LastPage>0032</LastPage>
<Language>EN</Language>
<AuthorList>

	<Author>
	<FirstName>Rajesh</FirstName>
	<MiddleName></MiddleName>
	<LastName>Dandale</LastName>
	<Affiliation>University of Verona Medical School, Verona, Italy.</Affiliation>
	<AuthorEmails>flavio.ribichini@univr.it</AuthorEmails>
	</Author>
	
	<Author>
	<FirstName>Carlo</FirstName>
	<MiddleName></MiddleName>
	<LastName>Zivelonghi</LastName>
	<Affiliation>University of Verona Medical School, Verona, Italy.</Affiliation>
	<AuthorEmails></AuthorEmails>
	</Author>
	
	<Author>
	<FirstName>Flavio</FirstName>
	<MiddleName></MiddleName>
	<LastName>Ribichini</LastName>
	<Affiliation>University of Verona Medical School, Verona, Italy.</Affiliation>
	<AuthorEmails></AuthorEmails>
	</Author>
	
	</AuthorList>
<DOI> </DOI>
<Abstract>




Despite the less invasive nature of trans-catheter aortic valve implantation (TAVI ) compared to conventional surgical aortic valve replacement, the trans-catheter procedure is not free of relevant complications such as vascular complications, renal function impairment, stroke, coronary occlusions and aortic rupture.Vascular complications significantly influence the immediate, mid and long-term clinical outcome; renal function impairment is also serious concern since most TAVI candidates have poor kidney function; stroke is the most threatening pitfall of TAVI since so far, its occurrence is largely unpredictable and hardly avoidable and lastly coronary occlusions and aortic rupture are rare but potentially fatal events. But all of these can likely be contained with an accurate pre-intervention selection of patients and techniques.In this article, we describe some challenging cases as examples to disclose the strategies applied for the management or prevention of complications in the experience with TAVI started in mid2010 and since over 100 patients with high risk symptomatic aortic stenosis were treated in the University of Verona, Italy, using full percutaneous transfemoral approach with the use of closure device.

</Abstract>
<Keywords>aortic stenosis, trans-catheter aortic valve implantantation, aortic valve surgery</Keywords>
<URLs>
	<abstract>http://www.raci.com.ar/contenido/art.php?recordID=NzUw</abstract>
	<Fulltext>
		<pdf>http://recursos.meducatium.com.ar/contenido/articulos/2900180032_750/pdf/2900180032.pdf</pdf>
	</Fulltext>
</URLs>

	</Article>
</ArticleSet>